The cooker faults you are expected to spot, why each one is dangerous, and the first thing to do about it.
These checks concern conventional flueless domestic cookers. Each fault below comes with the reason it matters.
- Yellow, sooty flames and staining above the hob: incomplete combustion, which can produce CO. A correct natural-gas burner shows mainly stable blue flames. Investigate the burners, aeration and ventilation before further use.
- Burner cap or pan support out of position: a mis-seated cap distorts the flame pattern and combustion. Pan supports only locate the pan; they do not set the gas rate or flame height.
- Failed flame supervision: gas still passes with no flame after the maker’s permitted shut-off or restart sequence. Some gas can pass during the response interval; continued flow beyond it is a safety failure. Take the affected burner or appliance out of use, investigate and prove the repair.
- Combustibles too close to the hob: burner heat can char and ignite units, shelves or a hood. Get the chosen cooker's clearances and anti-tip method from its fitting instructions, then check the applicable cooker and gas requirements. The old gap and the data badge cannot tell you either.
- Anti-tip restraint missing or not reconnected: the cooker can tip when weight goes on the open oven door, causing scalds and straining the gas connection.
- Isolation valve boxed in behind a screwed panel: the gas cannot be shut off quickly in an emergency or before work. Readily accessible means without tools.
- Vent taped over: the flueless cooker loses the combustion air it relies on, risking incomplete combustion and CO. The vent must be reopened.
- Cooker used for room heat: a normal cooker is made for cooking, not space heating. Extended use adds moisture and other combustion products to the room; a burner fault or inadequate replacement air can also produce CO. Stop the misuse and check the appliance and ventilation.
- Powerful extractor with an open-flued appliance in the same room: it can reduce room pressure and make that appliance spill. Carry out its prescribed spillage checks using the relevant fan and door combinations, including the adverse combination.
- Recirculating hood counted as ventilation: it returns filtered air to the room instead of discharging the combustion products outdoors.
If a user has a headache while the cooker is used this way: treat CO exposure as possible. Stop using the appliance if safe, get everyone outside and seek urgent medical advice. Stay out until advised it is safe to return. Do not put the cooker back in use until its safety has been checked.
Also remember:
- LPG is heavier than air, so a leak can pool low down, in floor voids, basements or drains.
- Gas work carried out as a business requires an engineer competent for that appliance, working for a Gas Safe registered business. Competence is also required for unpaid gas work.
Ignition sparks and cleaning
On the Rangemaster Excel 110 Dual Fuel, pushing in a hotplate control operates the igniters at all the burners. A burner that is not being used can therefore still spark. Keep cleaning and dismantling away from the hotplate while any burner is on: the manual identifies an electric-shock risk. Follow the appliance's isolation and cooling instructions before cleaning.
This shared ignition action does not mean every burner receives gas. Each burner retains its own control and flame supervision. For lighting and commissioning checks, see commissioning a gas cooker.