Why a flexible connection

A suitable flexible connection permits the movement specified for a freestanding cooker. A sound bayonet socket closes when its plug is deliberately released and withdrawn; pulling on the cooker is not an automatic disconnection or shut-off method. Follow the connector and appliance instructions, including restraint release and re-engagement. The hose carries gas; it is not a pressure regulator, flue or earth.

Choosing the hose

  • Connect a cooker with the approved rigid arrangement or a cooker-rated flexible hose and bayonet. These withstand the heat and movement at the appliance and make a sound joint; improvised tubing does not.
  • Check the hose marking and approval against the gas in use. Some hoses are natural-gas-only; others are approved for both natural gas and LPG. You cannot tell compatibility by looking.
  • Do not make up a cooker connector from garden, fuel or water tubing and clips. Use the approved assembly and end fittings; extra sealant cannot make an unsuitable connection acceptable.

Routing

Fit the socket facing downwards so the hose hangs in an easy loop with some slack. The loop must remain free of stretching, kinks and trapping during the positioning allowed by the maker. Disconnect the bayonet before moving the cooker out for cleaning; flexibility is not permission to exceed the instructed movement. The hose must not:

  • be pulled taut, which strains the bayonet
  • be kinked, which restricts gas flow and stresses the hose
  • be crushed behind the cooker when it is pushed back
  • touch a surface prohibited by the appliance or hose instructions, such as a hot oven flue outlet

Cooker hoses can be rubber-based or corrugated metal assemblies, with different coverings, seals and bend limits. Neither a metal construction nor a braid makes every hot contact acceptable. Inspect the actual assembly and its route; a sound bayonet joint does not mean the hose is undamaged or correctly routed.

Faults and the fix

  • Perished, cracked or damaged hose: it can leak, so replace it.
  • Hose squashed behind the cooker or draped on a hot panel: follow the isolation, disconnection and movement procedure to gain access. Inspect the hose, replace it if damaged, and restore the specified route and restraint before use.

After connecting, complete the soundness checks appropriate to the gas work and connections before use. Keep the isolation point and bayonet accessible, and confirm the restraint is engaged again.

Reading the model's hose specification

For the Rangemaster Excel 110 Dual Fuel on LPG, check three requirements together: a connector rated for 50 mbar, capable of a 70 °C temperature rise, and identified in red by a stripe, band or label. A higher pressure capability cannot compensate for an inadequate temperature capability. The pressure figure describes the hose rating, not the pressure to set at the appliance; a temperature rise is measured above the surrounding temperature, not from 0 °C.

The Rangemaster Classic 60 Gas instead specifies 50 mbar and a 90 °C temperature rise for its LPG hose. Do not transfer the Excel 110's lower temperature figure to this model. Read the actual hose approval as well as the appliance instructions; colour alone does not show it is suitable.

Length is also part of the model's arrangement:

  • The Excel 110 accepts 900 mm and suggests 1,250 mm for more freedom in placing the bayonet and moving the cooker. The reason is fitting and movement, not a different pressure setting.
  • The Stoves 60 cm installation guide specifies 900–1,125 mm.
  • The Classic 60 Gas limits its hose to 1,500 mm.

A permitted length still needs a safe route, bend radius and connection, with the restraint correctly set. Extra length cannot justify trapping the hose or touching the oven flue.