A method for diagnostic questions, plus the recurring symptom patterns in plumbing and heating.
Diagnostic questions are not asking you to know one fact. They give you a symptom and ask which cause best explains it, so the skill being tested is reasoning, not recall.
A method that works on any of them
- State the symptom precisely, including when it happens. "Cold radiator" and "cold radiator only
when the neighbouring valves are open" are different faults.
- Decide which system it belongs to — supply, hot water, heating circuit, or above-ground drainage.
Half the wrong answers in a scenario question come from another system entirely.
- Check the simple, local, accessible things first. Many faults have simple causes, and a check
costs minutes while a strip-down costs a day. This is not because complex faults are rare; it is because the cheap checks either find it or narrow it.
- **Prefer the cause that explains *all* the evidence**, including the parts that seem incidental.
- Prove it before you replace anything. Swapping parts until the symptom goes is not diagnosis.
One useful rule: a fault affecting one outlet is usually local to that outlet, and a fault affecting several is usually upstream of them all.
The patterns that keep coming up
Trap seals and drainage. A basin trap that loses its seal after a long waste run was added points to self-siphonage — the waste arrangement itself is pulling the seal out. A trap that *gurgles* when another appliance discharges points instead to drainage ventilation and seal disturbance.
Flow balance in heating. A pump that becomes noisy as most thermostatic valves close is seeing excess differential pressure with no bypass route left open. A radiator that heats only while nearby valves are open is a flow-balance or control-interaction problem, not a failed radiator.
Sizing against duty. A room that stays cold after a radiator was swapped for a smaller decorative model has an emitter whose output no longer matches the room heat loss. Nothing is broken; the design is.
Pressure loss. A sealed system losing pressure overnight with no visibly wet valve is a leak, a relief valve passing, or an expansion-vessel fault — and a tundish discharging intermittently on an unvented cylinder is the same family: a control, expansion or safety-valve fault needing competent assessment, never something to leave running.
Local restriction. One new tap running weakly while its neighbours are fine is a local isolation valve, aerator or tap connector, not the street main.
Stagnation and hygiene. Warm, stale water at first draw-off from a little-used outlet means low turnover or heat gain in that branch. A storage cistern with slime, a missing lid and warm water is a water-quality defect and is treated as one.
*Original revision guidance; confirm design and hygiene detail against the cited public sources.*