Fault finding: reasoning to the likely cause

Note 5 of 5 · free to read

A method for diagnostic questions, plus the recurring symptom patterns in plumbing and heating.

A symptom tells you where to look, but rarely which part has failed. Build the diagnosis from the pattern, safe observations and measurements, then check the repair worked.

Work through the evidence

  1. Find out the symptom, when it happens and what changed recently.
  2. Identify the actual system and its supplies: direct or stored water, heating circuit, hot-water path or drainage.
  3. Protect people, and make access and isolation safe, before you operate or open anything.
  4. Check the supplies, settings and flow paths you can reach, in the manufacturer’s order.
  5. Compare affected and unaffected outlets under the same demand, then test the cause you suspect before replacing parts.

One affected outlet usually means checking locally first; several point to a shared path. Either way, there may be more than one fault, or a shared part that behaves differently at different loads.

Water flow and storage

For a tap that has gone weak, check its service valve, connector, strainer and aerator, and compare it with other taps on the same supply. A good cold side does not explain a weak hot side. If hot water is only slow to arrive, measure the draw-off rate and allow for the cooled water sitting in the branch. That water in a working branch is different from a capped-off dead leg.

If the direct mains kitchen tap works but several cistern-fed taps are weak, check the cistern level, refill, outlet valves and shared branches first. Closing the incoming stop tap does not stop stored water already feeding the system. If water keeps coming after you isolate, look for water left in the pipes, stored feeds and passing valves. Draining down does not stop water still coming in.

If the whole house has slowly got worse, measure pressure and flow and inspect shared valves, pressure reducers and filters where fitted. The supply, and several small restrictions, can also change over time. On a gravity-fed system, height gives the static head and pipe resistance affects the flow. A pump or a mains conversion needs a suitable design and enough water.

Heating hydraulics and controls

Noise that starts as TRVs close can come from higher differential pressure or a missing minimum-flow path. Check the pump curve or control mode, valve settings, minimum-flow route and actual measurements. Not every design needs a bypass. A radiator that warms only when other controls open needs both its demand signals and the hydraulic interaction checked; balancing alone may not cure it.

One cold radiator among working ones points to its valve, head, lockshield, air and branch flow. A cold top usually means air; a bottom that stays cold can mean sludge or poor circulation. A normal temperature drop across a radiator is not a sign of sludge. Bleed it by the maker’s safe method with the heating cool, then check the pressure. If air or pressure loss keeps coming back, find out why.

A humming pump does not mean water is circulating. Check the demand, valve positions, air, settings, restrictions and the pump’s mechanical condition. Some pumps vent themselves and have no bleed screw: follow the specified method, and safely isolate the electrics and deal with hot-water pressure before servicing. Draining down or altering pipework can let in air or debris, or change valve settings, so check for those too.

If a room stays cold after a radiator is replaced, check the flow and controls first. Then compare the radiator’s rated output at the design temperatures with the room’s heat loss. A catalogue output quoted for other temperatures cannot be compared directly. A room that overheats with its TRV turned down may have unwanted flow through the radiator, or heat from a source the valve cannot control. A TRV cannot cool a room.

Pressure and safety discharge

Compare sealed-system pressures at the same cold condition, and check the gauge where needed. Leaks, a passing relief valve and too little expansion capacity are all possible. Expansion trouble can cause too much pressure when hot, discharge, and then low pressure once cool. Follow the model’s filling instructions: repeated top-ups add oxygenated water and hide the cause.

Water running into an unvented cylinder’s tundish in normal use needs a competent person to assess it. Identify which valve is discharging and check the expansion space, inlet pressure, valve seating and temperature controls. A deliberate valve test is different from discharge that keeps happening. Keep the route clear and beware of hot water; never cap it, and do not assume the cylinder must be replaced.

Compare operating modes carefully

Heating that works on one call shows that mode works, not every part under another demand. On an instantaneous combi, working radiators with cold hot taps point first to how it detects a tap opening. Then check the diverter and the heat transfer to the domestic water. If the hot taps work but the radiators are cold, check the heating demand and circulation first. Storage combis are arranged differently, so work from the actual circuit.

With a separate cylinder, if the radiators work but the stored water is cold, check the cylinder’s schedule, thermostat, valve and coil flow first. If the immersion heats the water but the boiler does not, check the boiler demand and the primary heat path to the coil. The immersion working tells you nothing about the coil, the cylinder’s condition or the water quality. In a two-zone system, check the cold zone’s call, valve and flow before ruling out shared parts.

Traps and waste flow

A trap that loses its seal when its own appliance empties may be self-siphoning; one disturbed when another appliance drains points to induced pressure changes. Gurgling alone cannot tell suction, positive pressure and a blockage apart. Inspect the branch length, bore, gradient, ventilation and remaining seals. Any trap or air-admittance protection must suit the drainage design.

A trap that is rarely used can lose its seal by evaporation. Refill it, and look for another cause if the smell or seal loss comes back. For one slow sink, start at its strainer, trap and branch, then work outwards. Another fitting draining normally does not rule out a shared restriction. A lost seal explains a smell getting in, but not slow draining.

Water quality

Warm or stale water at the first draw from a little-used branch suggests poor turnover or heat pick-up. Review its use, route, insulation and the hygiene plan, and remove redundant pipework. A warm, uncovered cistern with deposits in it is a hygiene concern to assess and put right. It does not prove any particular organism is present. Restore proper protection and arrange cleaning or disinfection as required.

Colour or taste that appears after an appliance or hose is used calls for a check for backflow and cross-connections. Changes in flow can also stir up sediment. Protect the people drinking the water and get the supplier’s advice; do not decide the cause from timing alone. Choose backflow protection for the highest fluid category risk, including the substance and its concentration.

After work on the main, brown or gritty water may be stirred-up deposits. Follow the supplier’s flushing advice at the direct cold tap, and keep the debris out of hot-water storage and appliances. If it carries on or comes back, stop flushing and contact the supplier. Milky water that clears from the bottom of the glass upwards is usually harmless air bubbles. That does not rule out other contaminants. Cloudiness that stays, or an unusual taste or smell, still needs advice.

Brown water at several hot outlets while the incoming cold is clear points first to the hot store and pipework. Deposits from the main may still be in storage, or hot-side parts may be rusting. How the water looks does not prove a corroded cylinder or a leaking indirect coil.

Joints, valves and intermittent leaks

Before opening a metal compression joint to inspect its olive or tube, isolate and depressurise it. Follow the fitting maker’s tightening and testing sequence: some allow a limited extra turn on a fully inserted new joint during a controlled low-pressure test. That never allows opening a joint under pressure, or tightening it again and again blind. Compression joints on wastes may use rubber or shaped washers instead; follow that fitting’s assembly instructions and take any strain off the pipe.

If a plastic push-fit joint leaks or pulls apart, check the insertion depth and the insert the system needs. The pipe end must be square and undamaged; check the grip ring, seal and support too. Follow that system’s pipe preparation: some need a damaged or burred plastic end cut back, not scraped down. If a new mixer gives the temperatures the wrong way round, check its inlet connections and cartridge orientation. Ordinary internal crossflow rarely swaps them exactly.

A running cistern warning pipe usually leads to checking the float valve and water level, but water can get in other ways. For a WC trickling into its pan, watch whether the level rises to the internal overflow or drops through a leaking flush seal and is then topped up. Find the actual cause before renewing parts.

For a ceiling stain that comes and goes, first deal with any electrical or structural hazard. Match it to when things are used, and do safe, controlled checks of supplies, wastes and seals. Allow for condensation and water tracking from elsewhere, and never flood anything on purpose to prove a leak.

Other system clues

For a gutter overflowing at one outlet, check debris, the downpipe, support, alignment and the product’s designed level or fall. Overflowing at one point can still mean the gutter is too small for the area it drains, or blocked further down.

A heat pump reporting low water flow after alterations points first to the water side: flow paths, strainers, air, pump and balancing. Check the real flow and the sensor reading against the maker’s requirements; the controls and built-in parts may still need checking.

Stored greywater that smells needs its storage time, treatment, turnover and cleaning reviewed, including any pumps and filters that support the treatment. A sudden bang as a valve closes suggests water hammer: supports stop the pipe moving, while a suitable hydraulic control deals with the pressure wave.

Stop routine diagnosis for an immediate hazard

A gas smell, a CO alarm or possible exposure means protecting people and getting emergency help from somewhere safe. In Great Britain the mains gas emergency number is 0800 111 999; get prompt medical advice for possible CO symptoms. Business gas or combustion work in a home belongs with a suitably qualified Gas Safe engineer where registration is required. The law’s few exceptions still need competence. Keep any other work within your competence and clear of the gas side.

If a boiler locks out again after a permitted reset, follow its fault guidance and stop resetting it. A reset restarts the sequence with its safeguards still working, but it does not fix the fault. Never keep topping up the pressure or switching it off and on to keep it running. Refer the specialist work and keep people safe before carrying on.