Domestic Fuels (L3)

Heat pumps: air source and ground source

Note 5 of 12 · free to read

How ASHP and GSHP move low-grade heat, why flow temperatures are low, and what good design depends on.

Moving heat rather than burning fuel

An electrically driven domestic heat pump transfers environmental heat without burning fuel. It uses a refrigeration cycle to move low-grade heat from outside into the home, raising it to a useful temperature. Because it moves heat rather than burning fuel, it can deliver several units of heat for each unit of electricity it uses.

Air source and ground source

  • Air source heat pumps (ASHP) take heat from outdoor air. They usually need less ground work than a ground-source system and suit many homes, subject to siting and design.
  • Ground source heat pumps (GSHP) take heat from the ground through buried loops or boreholes. The ground stays at a steadier temperature, which can improve efficiency, but installation costs more and needs space or drilling.

Efficiency and design

COP compares heat output with electrical input at stated operating conditions. A ratio of 3 to 4 means roughly three to four units of delivered heat per unit of electricity. That is a typical figure, not a guarantee. For seasonal comparisons, distinguish a declared SCOP under reference conditions from performance measured in a particular installation.

Heat pumps work best at low flow temperatures, often well below those of a gas boiler. Calculate the room heat losses and check emitter output at the proposed water temperatures. Existing radiators may be adequate; increase their output capability where the assessment shows a shortfall. Fabric improvements reduce demand, but not every home needs full insulation upgrades or underfloor heating first. Poor design leads to high running costs and discomfort.

Verify performance figures and design data against manufacturer information and recognised design guidance.

Design points that decide results

  • SCOP uses a defined reference heating season. Compare products at matching climate and water-temperature conditions. Measured seasonal performance also needs a stated period and a clear boundary for which pumps, controls and supplementary heaters are included.
  • A heat pump works best running steadily at a low flow temperature, which suits a well-insulated home with generous emitters.
  • At the same room temperature and otherwise comparable conditions, a lower mean water temperature reduces radiator output. Check each room’s load against emitter output at the proposed flow and return temperatures. Retain adequate emitters; where capacity falls short, assess suitable emitter changes or a revised design.
  • Take planned fabric improvements into account before sizing the system. Reduced demand can support lower operating temperatures and smaller required outputs; where improvements are impractical, design for the building as it is.
  • Leave the outdoor heat exchanger’s inlet and outlet clear to maintain airflow and avoid recirculating cooled discharge air. Follow the model’s siting, access and refrigerant safety-zone requirements. Condensate and defrost water need their own specified drainage route, with freezing and slip risks considered.
  • Hybrid controls may choose either source or operate them together. A common arrangement gives the heat pump much of the seasonal load and uses the boiler for additional capacity or hot water, but the actual split follows the design and operating conditions.