No hot water from a combi: a fault-finding checklist

Note 20 of 27 · free to read

An ordered set of checks for the common complaint of a combination boiler giving heating but no hot water, or none at all.

No hot water is one of the most common call-outs. Work from simple and external to internal and complex, and follow the manufacturer's fault-finding guide for the exact appliance.

  1. Get the story. No hot water at all, heating but no hot water, or only lukewarm? Did it stop suddenly or fade? Identify whether it is an instantaneous or a storage combi before following its hot-water circuit.
  2. Check the basics. Confirm the boiler has power, the gas is on and the system pressure is in range, and read any fault code before touching anything.
  3. Use the heating as evidence. Warm radiators show that the boiler fires and circulates water on a heating call. A total loss of power or gas is less likely, but a hot-water call and its flow path still need their own checks.
  4. Check the demand. On an instantaneous combi, confirm the appliance registers a hot-water draw-off. A flow sensor or flow switch fault can stop the demand while heating still works. A storage combi also has a store-charging circuit and controls to check.
  5. Check the path. Where the design uses a diverter valve and a separate plate heat exchanger, check that the valve moves to the hot-water position and that heat transfers, using the prescribed tests. Lukewarm hot water with normal heating points to diverter movement, flow detection or a scaled or blocked plate heat exchanger. These are possible causes; the symptom does not tell you which.
  6. Check the temperature controls. Confirm the hot-water setting and any thermistor reading are sensible; a faulty sensor can make the boiler behave oddly.
  7. Confirm combustion and safety. If it fires for hot water, confirm it is gassing and burning correctly and that the safety devices work.
  8. Prove and recommission. After a repair, prove the fix, recheck combustion and the controls, and leave the appliance working correctly.

Compare: stored hot water

With a separate cylinder, trace its call for heat through the programmer and cylinder thermostat. In S-plan, check the hot-water zone valve; in Y-plan, check the mid-position valve. Confirm primary water can reach the cylinder coil. Radiators heating makes a total loss of heat or circulation less likely, but it does not clear the shared parts that work on the cylinder call.