The common soil and waste appliances, the traps that serve them and why each is shaped as it is.

Sanitary appliances are the fittings people actually use, from basins to WCs, and each is paired with a trap and waste suited to its job.

They divide broadly into two groups. Soil appliances, chiefly the WC, deal with foul waste and connect to larger soil pipework. Waste appliances, such as wash basins, sinks, baths, showers and bidets, deal with used water and connect to smaller waste pipes.

Each appliance connection needs a suitable barrier against foul air. Conventional traps use a retained water seal; an approved waterless waste valve uses a self-closing membrane for its permitted applications. The distinction matters when selecting a fitting that may be left unused.

Trap shapes suit the appliance. A basin or sink often uses a tubular or bottle trap that is easy to fit and clean under the appliance; a bath trap must fit the space while retaining the required seal depth; a WC has its trap built into the pan.

Waste sizes suit the flow. A wash basin uses a smaller waste than a sink or bath, and a WC uses much larger soil pipework, because each carries a different amount and type of discharge. Approved Document H Table 1 puts figures on the traps: at least 32 mm for a washbasin or bidet; 40 mm for a bath, shower, sink, washing machine, dishwasher, food waste disposal unit or urinal bowl; and 75 mm or 100 mm for a WC pan, depending on whether its outlet is under or over 80 mm. The branch from a single appliance is at least as large as its trap.

The themes that follow are seal depth, branch length and ventilation, all aimed at keeping the seal in place so the appliance stays smell-free and drains properly. Check the right trap, seal depth and waste size for each appliance in Approved Document H.

Appliance overflows

Where a basin or bath has an overflow opening, rising water can pass through a second route to the waste even when the plug closes the main outlet. This opening does not control the taps. Keep its path clear and use the waste fitting specified for the appliance’s overflow arrangement.

How the WC flush restores its own seal

A WC flush does two jobs in one action: it washes the pan's contents through the pan's own integral trap into the branch, and the water it leaves behind re-forms that trap's seal. An adequate flush volume and pattern matters for both - too little water can fail to clear the pan or fail to leave enough behind to reseal it.

What may flush a WC

Schedule 2 of the Water Fittings Regulations allows a WC pan to be supplied from a flushing cistern, a pressure flushing cistern, which uses the supply pressure to compress air for the flush, or a pressure flushing valve fed straight from the pipework. A pressure flushing valve must not be fitted in a house, or in any building where a flow of 1.2 litres a second cannot be reached at the appliance. Until 1 January 2001 the rule was narrower: the cistern had to be the valveless type with a siphon, so cisterns from before then flush by siphon, and valve mechanisms such as drop valves have been allowed since. Every flushing cistern other than a pressure flushing cistern needs a warning pipe or an equally effective device. The guidance lets that warning pipe discharge into the pan itself, provided it discharges into the air at least 150 mm above the pan's top edge. No flushing device installed for a WC pan may give a single flush of more than 6 litres (7.5 litres until 1 January 2001), and on a dual-flush device the lesser flush may be no more than two-thirds of the largest, for example 4 litres beside 6. Every flushing cistern other than a pressure flushing cistern is marked inside with an indelible line showing its intended flush volume. A cistern installed before 1 July 1999 may be replaced by one delivering a similar volume, single or dual flush, but a single-flush cistern may not be replaced that way by a dual-flush one.

Controlled urinal flushing

A water-flushed urinal needs enough flushing to maintain hygiene and its trap seal. A control linked to occupancy or use avoids repeated flushing when it is unnecessary. Some controllers also give a hygiene flush after a period without use, so a urinal can still flush in an empty building. Follow the selected controller’s operation and maintenance instructions. An automatically operated urinal cistern may fill at no more than 10 litres an hour when it serves a single urinal, or 7.5 litres an hour for each bowl or stall, or each 700 mm of slab, when it serves two or more. A pressure flushing valve meets the same rule by delivering no more than 1.5 litres per bowl or position each time it operates. Unless the urinal is flushed by hand or by a sensor after use, its supply also needs a time switch or similar automatic control so the cistern fills only during set periods.

Approved Document G has a urinal with flushing apparatus discharge through a grating, a trap or mechanical seal, and a branch pipe to a discharge stack or a drain. Approved Document H's Table 2 lets an unventilated branch from a urinal bowl, trough or slab run up to 3 m, but asks for it to be as short as possible to prevent deposition, so that deposits do not build up inside it.

Trap patterns: P-traps, S-traps and waterless valves

P-traps discharge horizontally at the outlet, while S-traps turn downwards. The names describe those outlet directions; the pipework beyond them may follow different routes. That vertical drop can run full-bore as the appliance empties, siphoning the trap's own seal out behind it, which is why an S-trap is more prone to self-siphonage than a P-trap. A bottle trap offers a compact removable cup for cleaning. Select it by the manufacturer’s appliance suitability and rated flow, rather than assuming all bottle traps have one flow capacity. Suitable models also serve urinals. Where a conventional water seal would dry out from infrequent use, a self-sealing membrane waste valve is an alternative: it opens under flow and closes afterwards, blocking drain odours without relying on standing water that could evaporate. Follow its permitted applications, orientation and maintenance instructions.

Anti-siphon and resealing fittings stop suction pulling the seal out, but they work in different ways. An air-admitting type opens a valve to relieve the suction; a resealing type keeps back water to remake its seal. Neither stops the seal evaporating. Some bottle traps combine a water seal with a silicone membrane that remains a foul-air barrier when the water has gone. Check how the model actually seals; do not choose it by its shape or name.