Make sense of a thermistor reading by checking its temperature, response time and the correct resistance curve.
Resistance is the temperature signal
An NTC thermistor is a resistor whose resistance falls as its sensing element warms. NTC stands for negative temperature coefficient. Within its working range the resistance changes smoothly, unlike an on/off thermostat that just opens or closes a contact.
The resistance curve is nonlinear: the drop in resistance for one degree of warming is not the same at every temperature. A sensor that reads correctly at room temperature may still need checking at other points on its curve.
A reading needs a temperature
A reading such as 5.0 kΩ tells you nothing about the sensor until you know the element’s temperature and its specification. The boiler’s water pressure, a pump winding reading or the controller supply voltage cannot tell you that temperature.
Isolate and disconnect safely, as the appliance’s procedure says, before a resistance test. Compare the reading with the allowed band at the actual sensor temperature, not the boiler’s set temperature. Use the table for that component: no single resistance suits every boiler thermistor.
If the element checks out, still check its wiring and connections. Follow the whole fault-finding sequence before replacing a part.
Give heat time to reach the element
The resistance follows the temperature of the sensing element itself. When a cool probe goes into something warmer, heat takes time to reach it, so its reading moves towards the warmer value gradually.
Let the probe and the reference temperature settle under the set test conditions. A reading that is still changing during that time can be normal, so it is no reason to condemn the sensor. Swapping the leads over will not make it warm any faster.
How fast it responds depends on its construction, its mounting and what surrounds it, so no single waiting time suits every probe. Use a suitable measuring method too: too much measuring current can warm the element and upset the result.
One matching point is not a matching curve
The B value describes how resistance changes with temperature between two stated temperatures. Only compare B values quoted for the same pair of temperatures.
Two NTC sensors can read the same resistance at 25 °C and still have different B values for the same pair of temperatures. Away from 25 °C their curves then part, so a sensor that matches at room temperature can make the controller read the wrong temperature elsewhere in its range.
Use the replacement the appliance specifies. Its whole electrical characteristic, ratings, construction, mounting and connections all matter, so never choose a substitute from one resistance reading.